Power supply
Configuration
Example (B)
This riser has 20 floors, and each floor has 5 IUs. This power supply manages 1-2 floors.
If need open smart power function and power management function, the power supply
address is 12, max current of alarm sensor is 300 mA. System use MODE 2 configuration
method. Power supply configuration should be as following :
POSITION MODE 1 vAlUE FOr CONFIgUrATOr rEMArkS
CF1
N
0
CF2
N
1
CF3
N
2
CF4
FF Min
0
CF5
FF Min
1
CF6
#II
0
CF7
#II
5
CF8
FF Max
0
CF9
FF Max
2
CF10
CF10
Here configuration is not necessary
for mode 1 and mode 2
CF11
CF11
CF12
Type
1
CF13
ASR
0
CF14
M
0
CF15
LE
0
Example (B)