207
323005
Power supply
Choosing system power solution:
-
Solution 1
: PWS 323005 will be chosen as system power supply inside riser while
auxiliary PWS (323010) will be chosen for all the assistant power supply.
-
Solution 2
: PWS 323005 will be chosen for both system power supply inside riser and
assistant power supply.
Note: when the system has Small EP, solution 2 will be helpful to avoid possible damage
to the power supply in the system. When the system has IU connected with Small EP, at
some occasions, if several Small EPs call IU at the same time, it will make power supply
overloaded.
Under this situation, the power supply is at risk to be damaged.
Suggested power supply solution and related configuration:
Note: X = means no need any configurator, it also means the configurating position is 0; others need configurator with requested value. √ = means need configuration here.
Configuration
NO.
SYSTEM
PWS
SOLUTION
CONFIGURATION WHEN PWS IS SYSTEM POWER SUPPLY
(IMPEDANCE SWITCH OF PWS MUST BE ON)
CONFIGURATION OF PWS AND AUXILIARY PWS WHEN PWS IS
AUXILIARY POWER SUPPLY (IMPEDANCE SWITCH OF POWER
SUPPLY MUST BE OFF)
ALARM SMALL
EP
CF1
~
CF3
(NNN)
CF4
~
CF11
CF12
(TYPE)
CF13
(ASR)
CF14
(M)
CF15
(LE)
CF1
~
CF3
(NNN)
CF4
~
CF11
CF12
(TYPE)
CF13
(ASR)
CF14
(M)
CF15
(LE)
1
No
No
1
X
X
X
X
X
X
Here use Auxiliary Power supply, configuration is not necessary.
2
No
No
1
X
X
X
X
X
X
3
Yes
No
1
X
X
X
X
X
X
4
Yes
No
1
NNN
X
1
0.2–9
1
X
5
No
Yes
2
NNN
√
1
1
0/1
X
X
√
2
1
0/1
X
6
No
Yes
2
NNN
√
1
1
0/1
X
X
√
2
1
0/1
X
7
Yes
Yes
2
NNN
√
1
0.2~9
0/1
X
X
√
2
0.2–9
0/1
X
8
Yes
Yes
2
NNN
√
1
0.2~9
0/1
X
X
√
2
0.2–9
0/1
X
BT00453-b-en
13/05/2013
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...