2KJ/2KH
1-5-25
7. Remove two films from the scanner unit.
8. Move the mirror 1 frame to notch position.
When moving the mirror 1 frame, do not
touch the exposure lamp and the inverter
PWB.
Figure 1-5-40
9. Remove the connector of the exposure lamp
from inverter PWB and remove the lamp
wire from ribs.
Figure 1-5-41
10. Remove two screws and remove the expo-
sure lamp.
11. Replace the exposure lamp and refit all the
removed parts.
Figure 1-5-42
Film
Film
Mirror 1 frame
Connector
Inverter PWB
Lamp wire
Screw
Screw
Exposure lamp
Summary of Contents for TASKalfa 181