2KJ/2KH
1-3-10
U027
Return of backup data
Description
Transfers the backup data of the EEPROM which was transferred with the U026 to flash memory.
Purpose
To use after the main PWB replaced.
Method
1. Press the start key.
2. Select the [EXECUTE] using the cursor up/down keys.
3. Press the start key to transfer the backup data. The screen displays the result.
EXECUTE
CHECK SUM : ****
CODE : XXXX (See the table below)
4. Disconnect and connect the power plug.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U030
Checking motor operation
Description
Drives each motor.
Purpose
To check the operation of each motor.
Method
1. Press the start key.
2. Select the motor to be operated using the cursor up/down keys.
3. Press the start key. The operation starts.
4. To stop operation, press the stop/clear key.
Completion
Press the stop/clear key after operation stops. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Code
Description
0000
Processing ends correctly.
0203
Check sum does not agree when reading out from the EEPROM.
Display
Operation
MAIN
Drive motor (DM) is turned ON
DRUM
Drum motor (DRM) is turned ON
T1
Cassette drive motor 1 (CDM1) is turned ON
(option for 18 ppm model / standard for 22 ppm model)
T2
Cassette drive motor 2 (CDM2) is turned ON (option)
T3
Cassette drive motor 3 (CDM3) is turned ON (option)
EJE1
Eject motor (EM) is turned ON (forward)
EJE2
Eject motor (EM) is turned ON (reverse)
Summary of Contents for TASKalfa 181
Page 1: ...SERVICE MANUAL Published in October 2009 842KJ112 2KJSM062 Rev 2 TASKalfa 181 TASKalfa 221 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 14: ...2KJ 2KH This page is intentionally left blank ...
Page 114: ...2KJ 2KH 1 3 74 This page is intentionally left blank ...
Page 152: ...2KJ 2KH 1 4 38 This page is intentionally left blank ...
Page 292: ...INSTALLATION GUIDE FOR PAPER FEEDER ...
Page 306: ...INSTALLATION GUIDE FOR DUPLEX UNIT ...
Page 315: ...INSTALLATION GUIDE FOR BUILT IN FINISHER ...
Page 327: ...INSTALLATION GUIDE FOR JOB SEPARATOR ...
Page 336: ...INSTALLATION GUIDE FOR FAX System R ...
Page 351: ...INSTALLATION GUIDE FOR Scan System F B ...
Page 354: ......