2KJ/2KH
1-3-34
U100
Setting the main high voltage
Description
Changes the surface potential by changing the grid control voltage. Also performs main charging. Also
changes the setting of main charging copy quantity correction.
Purpose
To set the surface potential or check main charging. Also used when reentering data after initializing the set
data.
Start
1. Press the start key.
2. Select the item using the cursor up/down keys.
Method for main charger output
1. Select [MC ON] or [LASER ON/OFF] using the cursor up/down keys.
2. Press the start key. The selected operation starts.
3. To stop operation, press the stop/clear key.
Setting the grid control voltage
1. Select [MC DATA] using the cursor up/down keys.
2. Change the setting using the cursor left/right keys.
Increasing the setting makes the surface potential higher, and decreasing it makes the potential lower.
3. Press the start key. The value is set.
Setting the main charging copy quantity correction
1. Select the item using the cursor up/down keys.
2. Change the setting using the cursor left/right keys.
Copy interval: Sets the time interval from the previous copying. If the time from the previous copying
exceeds this preset value, the copy quantity counter will be reset.
Copy quantity: Sets the copy quantity from which copy quantity correction starts. When the copy quan-
tity counter reaches this preset value, correction will start.
Correction amount: Sets the correction amount for copy quantity correction.
Set the values in the range from 5 to 120 minutes for copy interval, from 10 to 2,000 sheets for copy
quantity, and from 5 to 50 bits for correction amount.
3. Press the start key. The value is set.
Completion
Press the stop/clear key when main charger output stops while a selection item is displayed. The screen for
selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
MC DATA
Changing the grid control voltage
MC ON
Turning the main charger on
LASER ON/OFF
Turning the main charger on and the laser scanner unit on and off
INTERVAL
Main charging copy quantity correction, copy interval
COPY CNT
Main charging copy quantity correction, copy quantity
MC ADJUST
Main charging copy quantity correction, correction amount
Description
Setting range
Initial setting
Grid control voltage
0 to 255
107
Display
Description
Setting range
Initial setting
INTERVAL
Copy interval
1 to 255 (minute)
60
COPY CNT
Copy quantity
1 to 255 (10 sheets)
50
MC ADJUST
Correction amount
0 to 50 (bit)
10
Summary of Contents for TASKalfa 181
Page 1: ...SERVICE MANUAL Published in October 2009 842KJ112 2KJSM062 Rev 2 TASKalfa 181 TASKalfa 221 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 14: ...2KJ 2KH This page is intentionally left blank ...
Page 114: ...2KJ 2KH 1 3 74 This page is intentionally left blank ...
Page 152: ...2KJ 2KH 1 4 38 This page is intentionally left blank ...
Page 292: ...INSTALLATION GUIDE FOR PAPER FEEDER ...
Page 306: ...INSTALLATION GUIDE FOR DUPLEX UNIT ...
Page 315: ...INSTALLATION GUIDE FOR BUILT IN FINISHER ...
Page 327: ...INSTALLATION GUIDE FOR JOB SEPARATOR ...
Page 336: ...INSTALLATION GUIDE FOR FAX System R ...
Page 351: ...INSTALLATION GUIDE FOR Scan System F B ...
Page 354: ......
Page 355: ......