9-S19
L4400 , WSM
ELECTRICAL SYSTEM
Connector Voltage
1. Turn the main switch OFF. Measure the voltage between the B
terminal (1) and the chassis.
2. Turn the main switch ON. Measure the voltage between the IG
terminal (3) and the chassis.
W1103012
No-Load Test
1. Connect the 2P connector (6) to previous positions of the
alternator after turning the main switch OFF.
2. Connect the jumper lead (3) between IG terminal (4) and B
terminal (2).
3. Start the engine and then set at idling speed.
4. Disconnect the negative cable from the battery.
5. Measure the voltage between the B terminal (2) and the chassis.
6. If the measurement is less than the factory specifications,
disassemble the alternator and check the IC regulator.
(Reference)
• Once the engine has started, the alternator temperature rises
quickly up to an ambient temperature of 70 to 90 °C (158 to 194
°F). As the temperature goes higher than 50 °C (122 °F), the
alternator voltage slowly drops; at higher than 100 °C (212 °F), it
drops by about 1 V.
W1102619
Voltage
(Main switch at OFF)
B terminal - Chassis
Approx. battery voltage
Voltage
(Main switch at ON)
IG terminal - Chassis
Approx. battery voltage
(1) B Terminal
(2) Alternator
(3) IG Terminal
(4) L Terminal
Voltage
Factory spec.
More than 14 V
(1) Voltmeter
(2) B Terminal
(3) Jumper Lead
(4) IG Terminal
(5) L Terminal
(6) 2P Connector
KiSC issued 07, 2007 A