RA83/84/85/93/94/95 Series
Chapter 10
Operation Manual
Technical References
10.4.4 Data input/output serial line (AIS)
Port name: AIS
The connector used:
Type LTWD-08PMMP-LC
Serial Data input (listener side):
The IEC61162-1 standard signal can be received
.
Input load: 94 ohms
Device:
RS422 Driver/Receiver IC
Type LT1791CS (Linear Technology)
Serial Data output (talker side):
The IEC61162-1 standard signal can be transmitted.
Device:
RS422 Driver/Receiver IC
Type LT1791CS (Linear Technology)
B Data Input
LT1791CS
IN-A 1
IN-B 1
Isolated from ground
A Data Input
Serial data input circuit
OUT-B
TX Data Output
OUT-A
LT1791CS
Isolated from ground
Serial data output circuit
Pin assignment on
Data Connector (Top view)
7
6
2
1
Data connector pin assignment
DATA 1,2 & 3
Pin No.
Name
1 Shield
2 IN-B
3 IN-A
4 OUT-B
5 OUT-A
6 GND
7 ALARM+
8 ALARM-
8
5
3
4
93142105-02
10-9