922-20207001/1.0
81
•
Parity
N
If required, a parity bit is used in a simple error detection algorithm for a serial
port.
•
Stop Bits
1
This parameter is used to indicate the end of the transmission. It is usually
set to
1
.
Target Marker format
$MSTRK,xx,hhmmss.ss,nnnnnnnn.nn,c,eeeeeeee.ee,c,U<CR><LF>
$MSTRK
Start character and prefix.
xx
Target number, ranging from 00 to 99.
hhmmss.ss
UTC time in hours, minutes, and seconds.
nnnnnnnn.nn
Northing or Latitude depends on the “U” definition.
c
N: North; S: South
eeeeeeee.ee
Easting or Longitude depends on the “U” definition.
c
E: East; W: West
U
‘f’: Northing/Easting in feet. Variable number of digits
for Northing/Easting and variable number of digits for
decimal-fraction of Northing/Easting.
‘m’: Northing/Easting in metres. Variable number of
digits for Northing/Easting and variable number of digits
for decimal-fraction of Northing/Easting.
‘l’: Lat/Lon in degrees. For Latitude: two fixed digits
of Latitude degrees, two fixed digits of minutes, and a
variable number of digits for decimal-fraction of minutes.
For Longitude: three fixed digits of Longitude degrees,
two fixed digits of minutes, and a variable number of
digits for decimal-fraction of minutes.
CRLF
Termination
Related topics