AKM Installation | 1 English
1.4.5 Insulation material class
The motors come up to insulation material class F according to IEC 60085 (UL1446 class F).
1.4.6 Surface
The motors are coated with polyester powder coating in matte black. This finish is not res-
istant against solvents (e.g. trichlorethylene, nitro-thinners, or similar).
1.4.7 Shaft end, A-side
Power transmission is made through the cylindrical shaft end A, fit k6 (AKM1: h7) to
EN 50347, with a locking thread but
without a fitted keyway
.
Motors are also available with keyway and inserted key according to DIN 6885. The shaft
with keyway is balanced with short (half) key.
Bearing life is calculated with 20.000 operating hours.
Order code Shaft end
Available for
N
Smooth shaft
all types, standard
C
Keyway, closed
AKM 2...8
K
Keyway, open
AKM 1...8
Radial force
If the motors drive via pinions or toothed belts, then high radial forces will occur. The per-
missible values at the end of the shaft may be read from the diagrams in chapter "Drawings"
from (
# 186). The maximum values at rated speed you will find at the technical data from
# 167). Power take-off from the middle of the free end of the shaft allows a 10% increase
in F
R
.
Axial force
When assembling pinions or wheels to the axis and use of e.g. angular gearheads axial
forces arise. The maximum values at rated speed are found in the technical data.
Coupling
Double-coned collets have proved to be ideal zero-backlash coupling devices, combined, if
required, with metal bellows couplings.
1.4.8 Shaft seal
If AKM is connected to a machine flange with unsealed shaft region, then the shaft seal
(option "01") ensures the shaft sealing.
l
The Teflon shaft seal ensures the IP67 protection for the shaft area.
l
The rated performance is achieved after some hours of shaft seal run-in. No special pro-
cedure for run-in is needed.
l
Some “shedding” of Teflon material is normal and does not affect the function.
l
Shaft seal operation in dry-running mode is prohibited. Contact Kollmorgen for special shaft
seal solution in case the dry-running operation is required.
l
Shaft seal is pre-lubricated by FDA grease.
1.4.9 Protective device
The standard version of each motor is fitted with an electrically isolated PTC (rated
temperature 155°C ± 5%). The PTC does not provide any protection against short, heavy
overloading.
The motor can be delivered with a PT1000 or KTY 84-130 sensors optionally (see Connector
Options 1, 2, 7 and D on (
16
Kollmorgen | kdn.kollmorgen.com | June 2018
Summary of Contents for AKM
Page 37: ...2 3 3 Typenschl ssel AKM Installation 2 Deutsch Kollmorgen kdn kollmorgen com June 2018 37...
Page 119: ...5 3 3 Cl de type AKM Installation 5 Fran ais Kollmorgen kdn kollmorgen com June 2018 119...
Page 138: ...AKM Installation 5 Fran ais 138 Kollmorgen kdn kollmorgen com June 2018...
Page 142: ...AKM Installation 6 100 C 40 C PE 60 142 Kollmorgen kdn kollmorgen com June 2018...
Page 147: ...6 3 3 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 147...
Page 161: ...6 6 200 6 6 1 10 60 PE EN 60204 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 161...
Page 163: ...6 7 6 7 1 900 10 60 100 C 40 C AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 163...
Page 164: ...AKM Installation 6 6 7 2 1 2 3 4 24 5 6 7 8 9 164 Kollmorgen kdn kollmorgen com June 2018...
Page 165: ...6 7 3 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 165...
Page 210: ...AKM Installation 11 Record of document revisions 210 Kollmorgen kdn kollmorgen com June 2018...
Page 211: ...AKM Installation 11 Record of document revisions Kollmorgen kdn kollmorgen com June 2018 211...