AKM Installation | 7 Technical Data
7.9 Technical Data AKM7 without fan
U
N
Data
Symbol
AKM
[Unit]
72K 72M 72P
72Q 73M 73P 73Q*** 74L
74P 74Q***
Electrical data
Standstill torque for
∆
T
winding = 100K*
M
0
[Nm]**
29.7 30.0 29.4 29.5 42.0 41.6
41.5
53.0 52.5
52.2
Standstill current for
∆
T winding = 100K
I
0rms
[A]**
9.3
13.0 18.7 23.5 13.6 19.5
24.5
12.9 18.5
26.1
Standstill torque for
∆
T
winding = 60K*
M
0
[Nm]**
23.8 24.0 23.5 23.6 33.6 33.3
33.2
42.4 42.0
41.8
max. Mains voltage
U
N
[VAC]
480
230VAC
Rated speed
n
n
[rpm]
—
—
1800 2000
—
1300
1500
—
—
1300
Rated torque*
M
n
[Nm]
—
—
23.8 23.2
—
34.7
33.4
—
—
41.9
Rated power
P
n
[kW]
—
—
4.49 4.86
—
4.72
5.25
—
—
5.71
400VAC
Rated speed
n
n
[rpm]
1500 2000 3000 4000 1500 2400
3000
1200 1800
2500
Rated torque*
M
n
[Nm]
25.1 23.6 20.1 16.3 33.8 28.5
25.2
43.5 39.6
31.5
Rated power
P
n
[kW]
3.94 4.94 6.31 6.83 5.31 7.16
7.92
5.47 7.46
8.25
480VAC
Rated speed
n
n
[rpm]
1800 2500 3500 4500 1800 2800
3500
1400 2000
3000
Rated torque*
M
n
[Nm]
24.0 22.1 18.2 14.1 32.1 26.3
22
41.5 35.9
27.3
Rated power
P
n
[kW]
4.52 5.79 6.67 6.65 6.05 7.71
8.07
6.08 7.52
8.58
Peak current
I
0max
[A]
27.9
39
56.1 70.5 40.8 58.6
73.5
38.7 55.5
78.3
Peak torque
M
0max
[Nm]
79.4 79.8 78.5 78.4
112
111
111
143
142
141
Torque constant
K
Trms
[Nm/A]
3.23 2.33 1.58 1.30 3.10 2.13
1.70
4.14 2.84
2.00
Voltage constant
K
Erms
[mVmin]
208
150
102
81.2
200
137
109
266
183
129
Winding resistance line-
line
R
25
[
Ω
]
1.36 0.69 0.35 0.26 0.76 0.38
0.27
0.93 0.47
0.26
Winding inductance
line-line
L [mH]
20.7 10.8
5.0
3.2
12.4
5.9
3.7
16.4
7.7
3.8
Mechanical data
Rotor moment of inertia J [kgcm²]
65
92
120
Pole number
-
10
10
10
Static friction torque
M
R
[Nm]
0.16
0.24
0.33
Thermal time constant
t
TH
[min]
46
53
60
Weight standard
G [kg]
19.7
26.7
33.6
Radial load permitted
F
R
[N]
see page (
Axial load permitted
F
A
[N]
see page (
Power cable acc. EN60204-1:2006 Table 6, Column B2
Minimum cross section
mm²
1
1.5
4
6
2.5
4
6
1.5
4
6
* Rated data with reference Aluminum plate 457mm x 457mm x 12.7mm
** Derating:
Brake motor option reduces continuous torque ratings by 1Nm.
Non-resolver feedback options reduce continuous torque ratings by:
AKM72 = 2.0 Nm
AKM73 = 2.7 Nm
AKM74 = 3.4 Nm
Motors with non-resolver feedback and brake option, reduce continuous torque by:
AKM72 = 3.9 Nm
AKM73 = 5.1 Nm
AKM74 = 6.2 Nm
For motors with optional shaft seal, reduce torque shown by 0.25 Nm and increase M
R
by the same amount.
*** Technical data with connector option H. In case of using the connector option C the standstill current is limited
to 23,5A.
Brake data for Brake options are listed in chapter "Technical Data Brakes" from (
180
Kollmorgen | kdn.kollmorgen.com | June 2018
Summary of Contents for AKM
Page 37: ...2 3 3 Typenschl ssel AKM Installation 2 Deutsch Kollmorgen kdn kollmorgen com June 2018 37...
Page 119: ...5 3 3 Cl de type AKM Installation 5 Fran ais Kollmorgen kdn kollmorgen com June 2018 119...
Page 138: ...AKM Installation 5 Fran ais 138 Kollmorgen kdn kollmorgen com June 2018...
Page 142: ...AKM Installation 6 100 C 40 C PE 60 142 Kollmorgen kdn kollmorgen com June 2018...
Page 147: ...6 3 3 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 147...
Page 161: ...6 6 200 6 6 1 10 60 PE EN 60204 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 161...
Page 163: ...6 7 6 7 1 900 10 60 100 C 40 C AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 163...
Page 164: ...AKM Installation 6 6 7 2 1 2 3 4 24 5 6 7 8 9 164 Kollmorgen kdn kollmorgen com June 2018...
Page 165: ...6 7 3 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 165...
Page 210: ...AKM Installation 11 Record of document revisions 210 Kollmorgen kdn kollmorgen com June 2018...
Page 211: ...AKM Installation 11 Record of document revisions Kollmorgen kdn kollmorgen com June 2018 211...