www.kolidainstrument.com
166
25. SPECIFICATION
TYPE
KTS-462R10L
Red visible laser
Carrier Wave
0.650 – 0.690 μm
Measuring system
Basic frequency 150MHZ
EDM type
Coxial
Minimum display
0.1mm
Laser facula
Non-reflector
About 7×14
㎜
/ 20m
With-reflector
About ×20
㎜
/ 50m
Weather correction
Manually input, Auto correction/ Sensor Auto Correction
Atmosphere reflection and earth
curve correction
Manually input, Auto correction
Prism constant correction
Manually input, Auto correction
Distance unit
meter
/
us.feet/international feet/feet-inch
Digit display
Max
:
99999999.999 m Min 1 mm
Average measuring times
The average value of 2- 5 times
Accuracy
With reflector
Distance measurement
Standard difference of accuracy
Measuring time
Prism fine
±(2mm+2ppm²D)
<
0.3s
Prism tracking
±(5mm+2ppm²D)
<
0.1s
IR sheet
±(2mm+2ppm²D)
<
0.3s
Non-reflector
Distance measurement
Standard difference of accuracy
Measuring time
Non-prism fine
±(3mm+2ppm²D)
<
0.3s
Non-prism tracking
±(10mm+2ppm²D)
<
0.1s
Measuring range
With reflector
Air condition
Standard prism
3 prisms
Sheet
(60mm*60mm)
5km
2700m
3200m
150m
20km
4500m
6200m
300m
Cloudy, 40km
5000m
7500m
300m
Non-reflector
Air condition
Non-prism
(
white
)‴
Non-prism grey 0.18