www.kolidainstrument.com
50
PROCEDURE
Operating Procedure
Operation
Display
1)
Sight at the target center point, select “1.
Observation” from the coordinate measurement
menu screen, then press OBS. (or press numeric key
1 directly).
Select
“1.Observ
ation”
+
OBS.
Coordinate
N
E
Z
ZA 0
°
00
′
00
″
HAR 0
°
00
′
00
″
Pt 1
Stn OBS.
2)
When measurement is completed, the coordinate
value and the distance of the target, the vertical
angle, and the horizontal angle are displayed. (If the
current measurement mode is set be repetition
mode, press STOP key to stop measuring and
display the measurement value.)
DIST
Fine[1]
N 120.00m
E 110.00m
Z 50.00m
ZA 273
°
18
′
15
″
HAR 150
°
18
′
15
″
STOP
Coordinate
*N 120.00m
*E 110.00m
*Z 50.00m
*Z A 273
°
18
′
15
″
*HAR 150
°
18
′
15
″
Pt 1
REC. Stn OBS.
3) To record coordinate data in JOB, press REC.
Input the following items:
1. Point number: target point number
2. Code: Codes or notes.
After each entry .press
▼
.
When the cursor is on the code line, code
function key show up automatically.
Press the code function key, code list popup, and
then press ▲▼ to select code.
Or read in the code by imputing its serial number
For example , imput 1 and its equivalent code could
be used.
VIEW: show code list, press ▲▼ to select code.
ENT: return to previous menu
SAVE: Save the data
REC.
+
SAVE
REC Coordinate
*N 120.00m
*E 110.00m
*Z 50.00m
Pt KOLIDA
Code 1VS
SAVE CODE
Quick Code
Number 1
VIEW OK