www.kolidainstrument.com
71
13. 2 Changing the Starting Point
·
It is possible to change the last measured point to the next starting point.
PROCEDURE
Operating Procedure
Operation
Display
1) Observe the start point and target following the
steps 1 to 3 in “Chapter 13.1 Measuring the distance
between multiple targets.”
MLM
MLM
S 10.00m
H 110.00m
V 60.00m
VA 273
°
18
′
15
″
HAR 150
°
18
′
15
MLM START D/C OBS.
2) Press START when the “Missing Line
Measurement Results Screen” is displayed.
Press START will change the last measured point to
the starting point.
START
MLM
Move
?
YES NO
3) Press YES, the last target measured becomes the
new start point. Refer to “13.1 Measuring the
Distance Between Multiple Targets”, perform
missing line measurement of the next target point.
YES
MLM
START
S 10.00m
H 110.00m
V 60.00m
VA 273
°
18
′
15
″
HAR 150
°
18
′
15
″
MLM OBS.