www.kolidainstrument.com
137
Weather
:
Press
to select (Fine, cloudy, light rain, rain, snow)
Wind
:
Press
to select (calm, gentle, light, strong, storm)
Mode
:
Press
to select (Fine[r], N-Fine, Fine[s], Tracking)
·
To set the atmospheric correction factor to 0 ppm: 0PPM
21.2 Recording backsight data
It allows you to record backsight point data by 2 ways
:
·
set backsight point by angle
·
set backsight point by coordinate
21.2.1 Set backsight point by Angle
It allows you to set backsight azimuth angle by inputting angle value directly.
Operation procedures
Key
Display
1) In Record menu screen, use ▲▼ to select “2.
Back sight data” setting(or press numeric key 2),
displays as right, choose“1. Angle”.
“1.
Angle”
REC BS
1. Angle
2. Coordinate
2) Input Azimuth and press OK key.
Input
Azimuth and
press
OK
Azimuth Setting
HAR 344°43′32″
Input H Angle
H Ang 0°00′00″
REC. OK
3) Sight at backsight point and press YES.
YES
Sighting BS
Sighting BS
HAR 0°00′00″
NO YES
4) Finish azimuth setting and returns to previous
menu
Record(1/2)
1.Stn Data
2. Back Sight data
3. Angle data
4. Dist data
5. Coord data
6. Dist+Coord data