www.kolidainstrument.com
23
7. POWER ON/OFF AND PREPARATION FOR MEASUREMENT
7.1 Power ON/OFF
PROCEDURE
·
Power ON
Operation
Display
Note
Press
POWER
After power on, instrument process self-check as left.
SD Card Connected
Checking the inserted SD card
Home Page
Date 2015/07/28
Time 17:18:35
Ver. 20150415
Type KTS-460R6-L
No. K76400
Job A:/JOB.JOB
MEAS MENU MEM CNFG
After Self-check, Home Page shows up.
²
Power OFF
Press and hold POWER for 3 seconds.
7.2 Vertical Angle Tilt Correction
When the tilt sensor is turn on, the value of automatic correction of vertical angle is displayed due
to instrument is not precisely leveled. (Press
★
key and then press F2 TILT).
To ensure an accurate angle measurement, tilt sensors must be turned on. You choose“
XYON
”
,
The display can also be used to level the instrument better.