![Kolida Total Station KTS-462R10L Manual Download Page 145](http://html1.mh-extra.com/html/kolida/total-station-kts-462r10l/total-station-kts-462r10l_manual_1990667145.webp)
www.kolidainstrument.com
145
5
)
When the self checking is finished, Press SAVE
to record data. System will creates a new point
number by adding “1” on the base of last point
number. user can use this number directly or create
another number by himself
In order to avoid duplicate record , the function key
REC will not show up until a new measurement
happens.
SAVE
REC/Dist+Coord.
N 100.364 m
E 234.897 m
Z 49.098 m
ZA 76°34′17″
HAR 64°22′10″
Pt K2010
OBS. OFFS AUTO
6) Press OBS to measure the coordinates again in
Record Mode.
OBS.
Dist
Fine[1]
N 3.735 m
E 3.224 m
Z 1.886 m
ZA 76°34′17″
HAR 64°22′10″
STOP
7) Press ESC to return to record mode screen.
ESC
Record(1/2)
1.Stn Data
2. Back Sight data
3. Angle data
4. Dist data
5. Coord data
6. Dist+Coord data
Perform distance measurement to record automatically by pressing: AUTO.
When this key is used, it is unnecessary to perform coordinate measurement in MEAS Mode. Press
AUTO on the “Record Mode Screen” to perform coordinate measurement and automatically
record the results. When this is done, the point number automatically increases 1 from the last
number and the code is unchanged. After measurement has been completed, the screen return to the
display which AUTO was not pressed yet.
To perform Offset measurement in Record Mode: OFFS
21.7 Reviewing JOB Data
·
It is possible to review the data within the JOB which is selected.
·
In advance allocate the function key to display VIEW. Refer to “20.1.1 Key Function Allocation.”
·
It is possible to search for data within the JOB by point number, but the note data can not be
searched.