www.kolidainstrument.com
44
·
The following preparations are needed for coordinate measurement.
Station point coordinates setting
Azimuth angle setting
· For the coordinate measurement method, see “7.4 Setting the Instrument Options”.
10.1 Entering Instrument Station Data
·
Before coordinate measurement, input instrument station coordinates, the instrument height, target
height.
·
Use a tape to measure the instrument height and target height.
·
It is possible to set coordinate data into instrument in advance.
·
It is possible to record the set instrument station data in the JOB which has been selected. For the
JOB selection method, see “18.1 JOB Selection”.
·
It is also possible to perform coordinate measurement when MENU (on the third page of the
MEAS mode) is pressed to enter Menu Mode, then select “1. Coordinate”.
PROCEDURE
Operating Procedure
Operation
Display
1) Press MENU under Home Page screen.
MENU
+
1
Home Page
Date 2015/07/28
Time 17:18:35
Ver. 20150415
Type KTS-460R6L
No. K76400
Job A:/JOB.JOB
MEAS MENU MEM CNFG
Menu
(
1/2
)
1. Coordinate
2. Set-Out
3. Offset
4. MLM
5. REM
6. Resection
2) Select “2. Stn Data” and press ENT (or press
numeric key 2) to input the station data.
“2.Stn
data”
+
OK
Coordinate
1. Observation
2. Stn data
3. Back sight data