![Kolida Total Station KTS-462R10L Manual Download Page 41](http://html1.mh-extra.com/html/kolida/total-station-kts-462r10l/total-station-kts-462r10l_manual_1990667041.webp)
www.kolidainstrument.com
41
3) When distance measurement is completed, a
short beep sounds, and the measured distance data
(s), vertical angle (VA), and horizontal angle (HAR)
are displayed.
DIST
Fine(r)
S 120.00m
H 110.00m
V 50.00m
VA 273
°
18
′
15
″
HAR 150
°
18
′
15
″
STOP
MEAS(1/3)
SHV
S 120.00m
H 110.00m
V 50.00m
VA 273
°
18
′
15
″
HAR 150
°
18
′
15
″
DIST D/C 0SET HSET
4) When repeat measurement is performed, press
STOP after displaying the measurement values to
finish distance measurement and display the final
results of the measurements.
STOP
MEAS(1/3)
SHV
S 120.00m
H 110.00m
V 50.00m
VA 273
°
18
′
15
″
HAR 150
°
18
′
15
″
P1
DIST D/C 0SET HSET
☆
The distance and angle which you measured in the last time will be stored in the memory until
the power is turned off. It is possible to display the measured values converted into the horizontal
distance, height difference, and the slope distance by pressing D/C. For the display method, see
“9.4 Review of Measured Data.”
☆
If the single measurement mode and N-times= N are selected, measurement automatically
stops after appointed measurements completed.
9.4 Review of Measured Data
·
The distance and angle you measured in the last time are stored in the memory until the power is
switched off. The distance measurement value, vertical angle, horizontal angle, and coordinates can
be reviewed, it is possible to display the distance measurement values converted into the horizontal
distance, elevation difference, and the slope distance by pressing [D/C].
· In advance allocate the function key to display [RCL]. For the allocation method, see “21.1.1 Key
Function Allocation”.