11.1 Distance Setting-Out Measurement
·
The point can be found based on the horizontal angle from the reference direction and the distance
from the instrument station.
· From the menu mode, selecting “2. Set-Out” also can perform setting-out measurement.
PROCEDURE
Operating Procedure
Operation
Display
1) Choose “2. Set-Out” from Menu mode, the
following screen will be shown.
Choose
“2.Set-Ou
t”
S-O
1.Observation
2.Set-Out
3.Stn data
4.Back sight data
2) After set Station Point and Backsight Point,
choose “2.Set-Out”. Move the cursor to Distance
and Angle column, input Setout distance and angle,
then press OK. (If there is no known point, station
point coordinate could be set to 0 or don‟t set it. Use
angle to set back sight point.)
Set station
point and
backsight
point,
choose
“2.Set-Ou
t”+
OK
S-O
Np 0.000m
Ep 0.000m
Zp 0.000m
Dist 123.000m
Ang.
150°16′54″
REC. READ R.HT OK