7.27
Section 7
Electrical System and Components
7
Solenoid Test Procedure
Solenoid Shift Style Starters
Disconnect all leads from the solenoid including
the positive brush lead a
tt
ached to the lower stud
terminal. Remove the mounting hardware and
separate the solenoid from the starter for testing.
Test 1. Solenoid Pull-In Coil/Plunger Actuation
Test.
Use a 12 volt power supply and two test leads.
Connect one lead to the
fl
at spade
S/start
terminal on
the solenoid. Momentarily* connect the other lead to
the lower large post terminal. See Figure 7-53.
When the connection is made the solenoid should
energize (audible click), and the plunger retract.
Repeat the test several times. If the solenoid fails to
activate, it should be replaced.
*NOTE: DO NOT leave the 12 volt test leads
connected to the solenoid for any time over
what is necessary for performing each of
the individual tests. Internal damage to the
solenoid may otherwise occur.
12 volt Test Leads
Momentary
Connection Only
Figure 7-53. Testing Pull-In Coil/Plunger Actuation.
Test 2. Solenoid Pull-In Coil/Contact Continuity
Test.
Use an ohmmeter set to the audible or Rx2K scale, and
connect the two ohmmeter leads to the two large post
terminals. Perform the preceding test (1) and check
for continuity. See Figure 7-54. The ohmmeter should
indicate continuity, if no continuity is indicated the
solenoid should be replaced. Repeat test several times
to con
fi
rm condition.
VOM Leads
12 volt Test Leads
Momentary
Connection Only
Figure 7-54. Testing Pull-In Coil/Solenoid Contact
Continuity.
Test 3. Solenoid Hold-In Coil Function Test.
Connect one 12 volt test lead to the
fl
at spade
S/
start
terminal on the solenoid, and the other lead
to the body or mounting surface of the solenoid.
Then, manually push the plunger
In
and check if the
Hold-In
coil holds the plunger retracted. See Figure
7-55. Do not allow the test leads to remain connected
to the solenoid for a prolonged period of time. If the
plunger fails to stay retracted, the solenoid should be
replaced.
Manually Push
Plunger In
12 volt Test Leads
Connect Only Long
Enough toTest
Figure 7-55. Testing Hold-In Coil/Function Test.
Summary of Contents for Comand Pro CH1000
Page 1: ...SERVICE MANUAL HORIZONTAL CRANKSHAFT CH940 CH1000...
Page 2: ......
Page 4: ......
Page 30: ...4 4 Section 4 Air Cleaner and Air Intake System...
Page 52: ...6 6 Section 6 Lubrication System...
Page 96: ...8 16 Section 8 Disassembly...
Page 110: ...Section 9 Inspection and Reconditioning 9 14...
Page 140: ...10 30 Section 10 Reassembly...
Page 141: ......