10.27
Section 10
Reassembly
10
Figure 10-106. Oil Sentry
TM
Pressure Switch
Location.
2. Connect the green wire lead to the Oil Sentry™
terminal.
Install Blower Housing and Cylinder
Shrouds
1. Align and install the blower housing. See Figure
10-107.
Mounting
Locations
Figure 10-107. Installing Blower Housing.
2. Secure the blower housing with the four shoulder
screws. Torque the screws to
4.0 N·m (35 in. lb.)
for initial installations, or
2.0 N·m (18 in. lb.)
for
reinstallations.
3. Install the two cylinder shrouds and secure
with the shoulder screws. Torque the screws to
4.0 N·m (35 in. lb.)
for initial installations, or
2.0 N·m (18 in. lb.)
for reinstallations. See Figure
10-108.
Mounting
Locations
Cylinder
Shrouds
Figure 10-108. Installing Cylinder Shrouds.
Install Control Panel (If Equipped)
1. Install the control panel to the main control
bracket and oil
fi
lter housing. Torque the M6
screw going into the oil
fi
lter housing to
10.7 N·m
(95 in. lb.)
into a new hole, or
7.3 N·m (65 in. lb.)
into a used hole. Torque the two upper M5 screws
to
6.2 N·m (55 in. lb.)
into new holes, or
4.0 N·m
(35 in. lb.)
into used holes. See Figure 10-109.
Control Panel
Key Switch
Indicator
Light
Control Lever
Knobs
Figure 10-109. Control Panel.
2. Connect the Oil Sentry
TM
indicator light wires.
3. Install the knobs onto the control levers.
Summary of Contents for Comand Pro CH1000
Page 1: ...SERVICE MANUAL HORIZONTAL CRANKSHAFT CH940 CH1000...
Page 2: ......
Page 4: ......
Page 30: ...4 4 Section 4 Air Cleaner and Air Intake System...
Page 52: ...6 6 Section 6 Lubrication System...
Page 96: ...8 16 Section 8 Disassembly...
Page 110: ...Section 9 Inspection and Reconditioning 9 14...
Page 140: ...10 30 Section 10 Reassembly...
Page 141: ......