3.4 Power requirements
Input voltage:
10.8 - 31.2 VDC
Power consumption:
Less than 4.5 W (at 24VDC)
AC Operation:
AC/DC rectifier PS-003A is required.
Input
voltage
range:
115 VAC or 230 VAC
3.5 Compass safe distance
Standard: 0.8m
Steering: 0.4m
3.6 Environmental conditions
(1) Temperature and humidity
Display unit: - 15° to + 55°C
Operating temperature
Antenna unit: - 25° to + 70°C
Humidity 93%
(+40°C)
(2) Vibration
The equipment operates normally under the following vibrating conditions.
2 - 5 Hz - 13.2 Hz: Amplitude ±1mm ±10 % (Maximum acceleration of 7 m/s
2
at 13.2 Hz)
13.2 Hz - 100 Hz: Maximum acceleration of 7 m/s
2
being applied
(3) Water proof
Display unit: IPX4
Antenna unit: IPX6
3.7 External dimensions and weight
External dimensions: Width x Height x Depth
Dimensions (WxHxD):
220 x 131 x 90 (mm)
Weight:
0.86
kg
Refer to Figure 3.1 for the exterior with dimensions.
Refer to Figure 3.2 for service space required.
Refer to Figure 3.3 for exterior of antenna unit with dimensions.