5-22 Application Operation
PLZ-U
Table5-3
Pin numbers and compatible connectors
Table 5-4
Pin arrangement of connector 1
*1.
Input: Low active, pulled up to 5 V through 10 k
Ω
(low level input voltage: 0 V to 1 V, high level input
voltage: 4 V to 5 V). The ENABLE pin is active at low level signal.
In the recalling of the ABC preset memories and setup memories, if multiple signals are set to low level,
the signal that is set to low level last is valid.
*2.
When ENABLE is at high level, the following operations cannot be executed from the panel: recalling a
preset memory, recalling a setup memory, and turning the load on.
*3.
Input: High active, pulled up to 5 V through 10 k
Ω
(low level input voltage: 0 V to 1 V, high level input
voltage: 4 V to 5 V). The ENABLE pin is active at low level signal.
*4.
Output: Open drain, output withstand voltage of 30 VDC, output saturation voltage of approximately 0.7 V,
and maximum output current of 100 mA
Pin No.
Manufacturer Compatible Connector
Note
Omron
XG5M-2032 or
XG5M-2035
XG5S-1001 (2 pcs.)
For discrete
wires
XG4M-2030
XG4T-2004
For
fl
at
cables
KEL
6200-020-601
Pin No.
Signal Name
Input/Output
Function
1
A
Input
*1
Recall preset memory A of all channels simultaneously
2
B
Recall preset memory B of all channels simultaneously
3
C
Recall preset memory C of all channels simultaneously
4
AUX
Reserved
5
MEM0
Recall the setup memory 0
6
MEM1
Recall the setup memory 1
7
MEM2
Recall the setup memory 2
8
MEM3
Recall the setup memory 3
9
ENABLE
Enable the turning on/off of the load, recalling of presets
ABC, and recalling of setup memories 0 to 3.
*2
10
LOAD ON
Input
*3
Turn on the load on all channels simultaneously
11
N.C.
N.C.
N.C.
12
N.C.
13
N.C.
14
N.C.
15
LOAD STATUS
Output
*4
Turns on when the load is on
16
ALARM STATUS
Turns on when the alarm is activated
17
+5VIF
5 V and maximum output current of 100 mA
18
N.C.
N.C.
N.C.
19
GND
GND
GND (chassis electric potential)
20
GND
1 2
1
1
2
2
19
20
20
19
Summary of Contents for PLZ-30F
Page 32: ...2 18 Installation and Preparation PLZ U ...
Page 58: ...4 14 Basic Operation PLZ U ...
Page 144: ...6 52 Remote Control PLZ U ...
Page 145: ...PLZ U Maintenance 7 1 Chapter 7 Maintenance This chapter explains the PLZ U maintenance 7 7 ...
Page 186: ...A 26 Appendix PLZ U ...
Page 190: ...I 4 Index PLZ U ...
Page 191: ......