PLZ-U
Appendix A-17
IEEE 488.2 commands
Channel commands
Measurement commands
SCPI Command
Description
Query
*CLS
Clears the status data structures.
N/A
*ESE
Sets the standard event status enable register bits.
Yes
*ESR?
Queries the standard event status register.
Query
only
*IDN?
Queries the identi
fi
cation string. (Manufacturer information)
Query
only
*OPC
Causes the device to generate the operation complete message in the standard event status register
when all pending selected device operations have been
fi
nished.
Yes
*RCL <value>
Restores the current settings of the device from a copy stored in local memory.
N/A
*RST
Performs a device reset. Con
fi
gures the PLZ-U to a known condition independent from the usage
history of the device.
N/A
*SAV <value>
Stores the current settings of the device to local memory.
N/A
*SRE
Sets the service request enable register bits.
Yes
*STB?
Reads the status byte and the master summary status bit.
Query
only
*TRG
Trigger command. This is analogous to the Group Execute Trigger interface message de
fi
ned in
IEEE 488.1. See section 6.1.4.2.5 of IEEE 488.2.
N/A
*TST?
Since there is no self-test function built into the PLZ-U, an ASCII character 0 is always returned in
the output queue in response to this query.
Query
only
*WAI
Prevents the device from executing subsequent commands or queries until the No Operation Pend-
ing
fl
ag becomes true. (*OPC?)
N/A
SCPI Command
Description
Query
Note 1
Note 2
INSTrument
[:SELect] {CH1|CH2|CH3|CH4|CH5}
Selects the channel to which commands are
applied using an ID.
Yes
1
:NSELect {1|2|3|4|5}
Selects the channel to which commands are
applied using a number.
Yes
1
:COUPle <list>
Speci
fi
es multiple channels to which commands
are to be applied.
Yes
1
:CATalog?
Queries the channels that can be used using num-
bers.
Query
only
1
:CATalog:FULL?
Queries the channels that can be used using IDs.
Query
only
1
:[SELect]:FOCus
{CH1|CH2|CH3|CH4|CH5}
Selects the channel whose settings are to be dis-
played.
Yes
3
SCPI Command
Description
Query
Note 1
Note 2
MEASure[:SCALar]:
:CURRent[:DC]?
Reads the measured current.
Query
only
1
:POWer[:DC]?
Reads the measured power.
Query
only
1
:VOLTage[:DC]?
Reads the measured voltage.
Query
only
1
MEASure:ETIMe?
Reads the elapsed time of measurement.
Query
only
3
Summary of Contents for PLZ-30F
Page 32: ...2 18 Installation and Preparation PLZ U ...
Page 58: ...4 14 Basic Operation PLZ U ...
Page 144: ...6 52 Remote Control PLZ U ...
Page 145: ...PLZ U Maintenance 7 1 Chapter 7 Maintenance This chapter explains the PLZ U maintenance 7 7 ...
Page 186: ...A 26 Appendix PLZ U ...
Page 190: ...I 4 Index PLZ U ...
Page 191: ......