PLZ-U
Application Operation 5-13
5.6.3
Example Sequence
This section describes the procedure of entering the following example sequence.
• Flow of the example sequence
In this example, we will create a program based on Fig. 5-10.
The program repeats steps 1 to 8 three times. After repeating the sequence three
times, the load is turned off and the sequence ends.
Fig. 5-10
Sequence execution example
Table 5-1
Sequence Program Creation Table
Program name: Example
Date:
By:
Channel numbers (1 to 5)
1 (PLZ150U)
Memo
Repeat steps 1 to 8 three times. After repeating the sequence three times,
turn off the load and end the sequence.
Operation mode
CC
Range (A)
H:30 (A)
RPT (1 to 9999)
3
Last load (OFF/ON)
OFF
Step Number
Value
Execution Time
Note
1
1 A
100 s
2
5 A
100 s
3
1 A
200 s
4
5 A
200 s
5
1 A
100 s
6
10 A
50 s
7
1 A
50 s
8
10 A
50 s
10A
5A
Execution (RUN)
Setting
STEP
1
2
3
4
5
6 7 8
(Step execution time)
1A