9.
Set the number of program loops.
Press the PRT key. Turn the rotary knob to set the number of program loops.
You can specify an in
fi
nite loop by setting RPT (the number of program loops)
to 9999.
10. Exit from sequence mode.
Press the SEQ key while holding down the SHIFT key (SHIFT + SW ON).
The SEQ (SHIFT + SW ON) key turns off and sequence mode is dis-
abled.
11. Set whether to turn off the load or keep the load turned on at the com-
pletion of the sequence.
Set last load in the con
fi
guration settings. For details, see section 5.9, “Con
5.6.2
Executing the Sequence
You can execute a sequence on a speci
fi
ed channel or on all channels simulta-
neously. To start the execution of a sequence, press the LOAD key. To stop, press
the LOAD key again.
• You can select whether to keep the load turned on or turn off the load at the com-
pletion of the sequence. For details, see “Last load” in section 5.9, “Con
• In CC mode, soft start is activated at the start of the sequence execution. There-
fore, the current will not reach the preset value during the soft start time. To avoid
this behavior, enter a 0 A setting in step 1 for a time longer than or equal to
fi
ve
times the selected soft start time or 20 ms, whichever is longer.
1.
Turn off the load.
2.
Enter sequence mode.
Press the SEQ key while holding down the SHIFT key (SHIFT + SW ON).
The SEQ (SW ON) key and SEQ indicator illuminate. Sequence mode is
enabled.
3.
Execute the sequence (turn on the load).
When the load turns on, the sequence is executed in order from step 1. If you
press the LOAD key of a channel, the sequence is executed only on the speci-
fi
ed channel. If you press the LOAD key of the frame, the sequence is executed
on all channels simultaneously. In this case, channels whose INDEP key is
turned on are excluded.
For a description of the INDEP key, see “INDEP key” on page 3-9.
There may be an offset of about 10 ms for a sequence on different channels to
be executed (load to turn on).
NOTE
Summary of Contents for PLZ-30F
Page 32: ...2 18 Installation and Preparation PLZ U ...
Page 58: ...4 14 Basic Operation PLZ U ...
Page 144: ...6 52 Remote Control PLZ U ...
Page 145: ...PLZ U Maintenance 7 1 Chapter 7 Maintenance This chapter explains the PLZ U maintenance 7 7 ...
Page 186: ...A 26 Appendix PLZ U ...
Page 190: ...I 4 Index PLZ U ...
Page 191: ......