PLZ-U
Application Operation 5-29
5.11 Parallel Operation
Parallel operation is possible on adjacent load units of the same type in the frame
(up to 5 units on the PLZ-50F).
The channel at the left end facing the front of the connected channels is the master.
Other channels are slaves.
Channels operating in parallel are considered a single channel. The total current and
resistance (conductance) are used for displaying and setting.
Within the same frame, a combination of parallel and single-unit operation is possi-
ble.
Fig. 5-21
Combination of parallel operation and single-unit operation
Table 5-6
The number of units in parallel and the capacity
M
S
S
M
S
M: Master
S: Slave
When parallel operation of 3 units and parallel operation of 2 units are combined
using the PLZ-50F
M: Master
U
U
M
S
S
S: Slave
U: Single load unit
When parallel operation of 3 units and single-unit operation of 2 units are combined
using the PLZ-50F
Number of Units in Parallel
PLZ70UA
PLZ150U
2
30 A / 150 W
60 A / 300 W
3
45 A / 225 W
90 A / 450 W
4
60 A / 300 W
120 A / 600 W
5
75 A / 375 W
150 A / 750 W