6-16 Remote Control
PLZ-U
*SRE
Sets the service request enable register bit or queries the current setting.
The service request enable register is used to select the summary messages in the
status byte register that will be able to perform service requests.
To clear the service request enable register, send *SRE 0. If the register is cleared,
service requests cannot be generated by status information.
Set command:
*SRE
Query command:
*SRE?
Example) Sending *SRE 8 sets bit 3 of the service request enable register. Each
time the summary bit (bit 3) of the QUEStionable status register in the
status byte is set, a service request message is generated.
*STB
Queries the contents of the status byte register and the MSS (master summary sta-
tus) message.
The response is in a weighted decimal notation format representing the status byte
register and the MSS message (bit 6). Therefore, the response to
*STB?
is the same
as the response obtained by serial polling except that bit 5 represents the MSS mes-
sage in place of the RQS message.
For details, see section 6.6, “Status Registers.”
Query command:
*STB?
*TRG
Trigger command.
This is the same as the Group Execute Trigger command de
fi
ned in IEEE 488.1.
See section 6.1.4.2.5 of IEEE 488.2.
Set command:
*TRG
*TST
Since there is no self-test function built into the PLZ-U, an ASCII character 0 is
always returned in the output queue in response to this query.
Query command:
*TST?
*WAI
Prevents the PLZ-U from executing subsequent commands or queries until the No
Operation Pending
fl
ag becomes true.
Set command:
*WAI
Summary of Contents for PLZ-30F
Page 32: ...2 18 Installation and Preparation PLZ U ...
Page 58: ...4 14 Basic Operation PLZ U ...
Page 144: ...6 52 Remote Control PLZ U ...
Page 145: ...PLZ U Maintenance 7 1 Chapter 7 Maintenance This chapter explains the PLZ U maintenance 7 7 ...
Page 186: ...A 26 Appendix PLZ U ...
Page 190: ...I 4 Index PLZ U ...
Page 191: ......