PLZ-U
Remote Control 6-49
Preset status
STAT:PRES
Speci
fi
c events are reported at a higher level by constructing status data and using
the status reporting system. These events are summarized in the required structures,
OPERation status register, and QUEStionable register.
The STAT:PRES command only affects the ENABle register and the transition
fi
lter
register of the status data structure.
The STAT:PRES command does not clear any event registers or any items from the
error/event queue.
To reset all event registers and the queue within the device status reporting system,
use the *CLS command.
For the device-dependent status data structure, the STAT:PRES command sets the
ENABle register to all 1s and sets the transition
fi
lter registers so that only positive
transitions are reported.
For status data required by SCPI, the STAT:PRES command sets the transition
fi
lter
registers so that only positive transitions are detected and sets the ENABle register
to 0. The settings of the service request enable register, parallel poll enable register,
memory registers related to the *SAV command, the PLZ-U address, output queue,
and power on status clear
fl
ag are not affected by this command.
Table 6-12 Preset values of registers that can be set by the user
Set command:
STATus:PRESet
Register
Filter/Enable
Preset Value
Operation
Enable register
0 s
Positive transition
fi
lter
1 s
Negative transition
fi
lter
0 s
QUEStionable Enable register
0 s
Positive transition
fi
lter
1 s
Negative transition
fi
lter
0 s
CSUMmary
Enable register
1 s
Positive transition
fi
lter
1 s
Negative transition
fi
lter
0 s
Summary of Contents for PLZ-30F
Page 32: ...2 18 Installation and Preparation PLZ U ...
Page 58: ...4 14 Basic Operation PLZ U ...
Page 144: ...6 52 Remote Control PLZ U ...
Page 145: ...PLZ U Maintenance 7 1 Chapter 7 Maintenance This chapter explains the PLZ U maintenance 7 7 ...
Page 186: ...A 26 Appendix PLZ U ...
Page 190: ...I 4 Index PLZ U ...
Page 191: ......