PLZ-U
Remote Control 6-41
STAT:QUES:NTR
Sets the negative transition of the QUEStionable status register, or queries the cur-
rent setting.
Set command:
STATus:QUEStionable:NTRansition
<status-enable>
Query command:
STATus:QUEStionable:NTRansition?
QUEStionable:INSTrument subregister
Table 6-7
QUEStionable:INSTrument status register
(STATus:QUEStionable:INSTrument)
STAT:QUES:INST
Queries the event of the QUEStionable:INSTrument subregister.
Query command:
STATus:QUEStionable:INSTrument
[:EVENT]?
STAT:QUES:INST:COND
Queries the condition of the QUEStionable:INSTrument subregister.
Query command:
STATus:QUEStionable:INSTrument
:CONDition?
STAT:QUES:INST:ENAB
Sets the QUEStionable:INSTrument subregister enable, or queries the current set-
ting.
Set command:
STATus:QUEStionable
:INSTrument:ENABle <status-enable>
Query command:
STATus:QUEStionable:INSTrument
:ENABle?
Bit
Bit Weight
Bit Name
Description
0
1
NOT USED
1
2
INSTrument1
2
4
INSTrument2
3
8
INSTrument3
4
16
INSTrument4
5
32
INSTrument5
6
64
INSTrument6
7
128
INSTrument7
8
256
INSTrument8
9
512
INSTrument9
10
1024
INSTrument10
11
2048
INSTrument11
12
4096
INSTrument12
13
8192
INSTrument13
14
16384
INSTrument14
15
32768
NOT USED
Always zero
Summary of Contents for PLZ-30F
Page 32: ...2 18 Installation and Preparation PLZ U ...
Page 58: ...4 14 Basic Operation PLZ U ...
Page 144: ...6 52 Remote Control PLZ U ...
Page 145: ...PLZ U Maintenance 7 1 Chapter 7 Maintenance This chapter explains the PLZ U maintenance 7 7 ...
Page 186: ...A 26 Appendix PLZ U ...
Page 190: ...I 4 Index PLZ U ...
Page 191: ......