TRIGger Command
PCR-WE Interface Manual
293
TRIG:ACQ:SOUR
Sets the condition (trigger source) for actually starting the measurement after the AC-
Quire trigger subsystem receives an INIT:ACQ.
Command
TRIGger:ACQuire:SOURce <character>
TRIGger:ACQuire:SOURce?
Parameter
Value:
IMMediate
Starts the measurement immediately (default)
BUS
Waits for a software trigger (a *TRG, TRIG:ACQ, or IEEE
488.1 get
̶
Group Execute Trigger
̶
command), and then
begin measuring
Settings are reset to default values when an *RST command is sent.
Example
TRIG:ACQ:SOUR BUS
Response: Characters