KIKUSUI Electronics Corp.
108
OUTP:PHAS:ON:LEV
Sets the output-on phase angle.
This command is valid for AC output when the output-on phase control is on (OUT-
P:PHAS:ON ON).
If the signal source is set to external signal source VOLT:EXT:INP:EXTDC:SIGN:-
SOUR EXT), this command is invalid.
Command
OUTPut:PHASe:ON:LEVel <numeric>
OUTPut:PHASe:ON:LEVel?
Parameter
Value:
0.0 to 360.0 (The default value is 0)
Unit:
DEG
Settings are reset to default values when an *RST command is sent.
Example
OUTP:PHAS:ON:LEV 90
Response: NR3