[SOURce:]VOLTage Command
PCR-WE Interface Manual
183
VOLT:EXT:INP:VPR:ADJ:OFFS
Sets the offset for when varying the voltage or frequency with the external analog sig-
nal.
Command
[SOURce:]VOLTage:EXTernal:INPut:VPRogram:ADJust:OFFSet <NRf_
ch>,<NRf_offset>
[SOURce:]VOLTage:EXTernal:INPut:VPRogram:ADJust:OFFSet? <NRf_ch>
Parameter
<NRf_ch> Channel to be configured
設定値:
0
Ch.A
1
Ch.B
2
Ch.C
Parameter
<NRf_offset> Offset
Value: -200 to 200 (The default value is 0)
Settings are reset to default values when an *RST command is sent.
Example
VOLT:EXT:INP:VPR:ADJ:OFFS 0,10
Response
:
NR3