[SOURce:]VOLTage Command
PCR-WE Interface Manual
185
VOLT:EXT:INP:VPR:STAT
Turns on or off the output of each channel for when varying the voltage or frequency
with the external analog signal.
Command
[SOURce:]VOLTage:EXTernal:INPut:VPRogram:STATe <NRf>,<boolean>
[SOURce:]VOLTage:EXTernal:INPut:VPRogram:STATe? <NRf>
Parameter
<NRf>
Value:
0
Channel A
1
Channel B
2
Channel C
Parameter
<boolean>
Value:
ON(1)
Output on
OFF(0) Output off (default)
Settings are reset to default values when an *RST command is sent.
Example
VOLT:EXT:INP:VPR:STAT 0,ON
Response: NR1