KIKUSUI Electronics Corp.
104
OUTP:IMP:REAL
Sets the resistance component of the output impedances.
This command is valid when the output impedance is on (OUTP:IMP ON).
Command
OUTPut:IMPedance:REAL <numeric>[,(@chanlist)]
OUTPut:IMPedance:REAL? [(@chanlist)]
Parameter
Value: Resistance component (The default value is 0.)
L range
H range
Single-phase
Single-phase
three-wire,
Three phase
Single-phase
Single-phase
three-wire,
Three phase
PCR1000WE
0
Ω
to 2000 m
Ω
--
0
Ω
to 8000 m
Ω
--
PCR2000WE
0
Ω
to 1000 m
Ω
--
0
Ω
to 4000 m
Ω
--
PCR3000WE2 0
Ω
to 667 m
Ω
0
Ω
to 2000 m
Ω
0
Ω
to 2 667 m
Ω
0
Ω
to 8000 m
Ω
PCR6000WE2 0
Ω
to 333 m
Ω
0
Ω
to 1000 m
Ω
0
Ω
to 1333 m
Ω
0
Ω
to 4000 m
Ω
PCR12000WE2 0
Ω
to 167 m
Ω
0
Ω
to 500 m
Ω
0
Ω
to 667 m
Ω
0
Ω
to 2000 m
Ω
PCR18000WE2 0
Ω
to 111 m
Ω
0
Ω
to 333 m
Ω
0
Ω
to 444 m
Ω
0
Ω
to 1333 m
Ω
PCR24000WE2 0
Ω
to 83 m
Ω
0
Ω
to 250 m
Ω
0
Ω
to 333 m
Ω
0
Ω
to 1000 m
Ω
PCR30000WE2 0
Ω
to 67 m
Ω
0
Ω
to 200 m
Ω
0
Ω
to 267 m
Ω
0
Ω
to 800 m
Ω
PCR36000WE2 0
Ω
to 56 m
Ω
0
Ω
to 167 m
Ω
0
Ω
to 222 m
Ω
0
Ω
to 667 m
Ω
Unit: OHM
Settings are reset to default values when an *RST command is sent.
Example
OUTP:IMP:REAL 50MOHM,(@1)
Response: NR3