PROG:EDIT:IMP:REAL
Sets the resistance component of the output impedance used in the sequence step.
This command is valid when the output impedance (PROG:EDIT:IMP) of the se-
quence is to be set.
Command
PROGram:EDIT:IMPerdance:REAL <step_NRf>,<real_NRf>[,@chanlist]
PROGram:EDIT:IMPerdance:REAL? <step_NRf>[,@chanlist]
Parameter
<step_NRf>
Value: 0 to 599 Number of the step that you want to configure
Parameter
<real_NRf>
Value: Resistance component (The default value is 0.)
L range
H range
Single-phase
Single-phase
three-wire,
Three phase
Single-phase
Single-phase
three-wire,
Three phase
PCR1000WE
0
Ω
to 2000 m
Ω
--
0
Ω
to 8000 m
Ω
--
PCR2000WE
0
Ω
to 1000 m
Ω
--
0
Ω
to 4000 m
Ω
--
PCR3000WE2 0
Ω
to 667 m
Ω
0
Ω
to 2000 m
Ω
0
Ω
to 2 667 m
Ω
0
Ω
to 8000 m
Ω
PCR6000WE2 0
Ω
to 333 m
Ω
0
Ω
to 1000 m
Ω
0
Ω
to 1333 m
Ω
0
Ω
to 4000 m
Ω
PCR12000WE2 0
Ω
to 167 m
Ω
0
Ω
to 500 m
Ω
0
Ω
to 667 m
Ω
0
Ω
to 2000 m
Ω
PCR18000WE2 0
Ω
to 111 m
Ω
0
Ω
to 333 m
Ω
0
Ω
to 444 m
Ω
0
Ω
to 1333 m
Ω
PCR24000WE2 0
Ω
to 83 m
Ω
0
Ω
to 250 m
Ω
0
Ω
to 333 m
Ω
0
Ω
to 1000 m
Ω
PCR30000WE2 0
Ω
to 67 m
Ω
0
Ω
to 200 m
Ω
0
Ω
to 267 m
Ω
0
Ω
to 800 m
Ω
PCR36000WE2 0
Ω
to 56 m
Ω
0
Ω
to 167 m
Ω
0
Ω
to 222 m
Ω
0
Ω
to 667 m
Ω
Unit: OHM
Example
PROG:EDIT:IMP:REAL 1,50MOHM
Response: NR3