![Keysight Technologies N6900 Series Operating And Service Manual Download Page 45](http://html1.mh-extra.com/html/keysight-technologies/n6900-series/n6900-series_operating-and-service-manual_1962217045.webp)
Supplemental Characteristics - Keysight N6900 Series
1 kW Characteristics
N6950A
N6951A
N6952A
N6953A
N6954A
Minimum compliance limits
Voltage priority:
Current priority:
100 mA
9 mV
50 mA
20 mV
25 mA
40 mV
16 mA
60 mV
13 mA
80 mV
Voltage programming
Range:
Resolution:
Resolution:
0.009 to 9.18 V
0.84 mV
0.21 mV
0.02 to 20.4 V
1.7 mV
0.42 mV
0.04 to 40.8 V
3.5 mV
0.84 mV
0.06 to 61.2 V
5 mV
1.25 mV
0.08 to 81.6 V
6.7 mV
1.68 mV
Current programming
Range-no dissipator:
Range-with dissipator:
Resolution:
Resolution:
–10.2 to 102 A
–102 to 102 A
30 mA
1.9 mA
–5.1 to 51 A
–51 to 51 A
15 mA
0.95 mA
–2.55 to 25.5 A
–25.5 to 25.5 A
8 mA
0.47 mA
–1.7 to 17.034A
–17.034 to 17.034A
5 mA
0.32 mA
–1.275 to 12.75 A
–12.75 to 12.75 A
4 mA
0.24 mA
Current measurement range
High range:
Low range:
-225 to 225 A
-11 to 11 A
-112.5 to 112.5 A
-5.5 to 5.5 A
-56.2 to 56.2 A
-2.75 to 2.75 A
-37.6 to 37.6 A
-1.84 to 1.84 A
-28.1 to 28.1 A
-1.37 to 1.37 A
Resistance programming
Range:
Resolution:
Accuracy:1
Accuracy:
0 to 0.1
Ω
0.8 µ
Ω
0.12% +1.6 m
Ω
*A
0.06% +1.6 m
Ω
*A
0 to 0.4
Ω
3.4 µ
Ω
0.12% +3.2 m
Ω
*A
0.06% +1.6 m
Ω
*A
0 to 1.6
Ω
13 µ
Ω
0.1% +6.4 m
Ω
*A
0.06% +1.6 m
Ω
*A
0 to 3.4
Ω
30 µ
Ω
0.1% +8.8 m
Ω
*A
0.06% +1.6 m
Ω
*A
0 to 6.4
Ω
54 µ
Ω
0.1% +12.8 m
Ω
*A
0.06% +1.6 m
Ω
*A
Voltage programming & measurement
TempCo:2
0.0022% +30µV
0.0022%+60µV
0.0022%+120µV
0.0022%+180µV
0.0022%+220µV
Current programming & measurement
TempCo2
High range:
High range:
Low range:
0.0057%+250µA
0.0035%+250µA
0.0042%+80µA
0.0058%+125µA
0.0035%+125µA
0.0045%+40µA
>0.0058%+60µA
0.0042%+60µA
0.0050%+20µA
0.0058%+40µA
0.0037%+40µA
0.0046%+12µA
0.0058%+30µA
0.0036%+30µA
0.0045%+9µA
Resistance programming
TempCo:
TempCo:
0.0068%
0.0046%
0.0070%
0.0049%
0.0070%
0.0054%
0.0070%
0.0050%
0.0070%
0.0049%
Over-Voltage Protection
Maximum setting:
Response time:3
Accuracy:
Accuracy:
10.8 V
<30 µs
0.03% +1.5 mV
0.03% +1 mV
24 V
<30 µs
0.03% +3 mV
0.03% +2 mV>
48 V
<30 µs
0.03% +6 mV
0.03% +4 mV
72 V
<30 µs
0.03% +9 mV
0.03% +6 mV
96 V
<30 µs
0.03% +12 mV
0.03% +8 mV
Voltage measurement noise (peak):4
2 mV
3.5 mV
7 mV
10 mV
14 mV
Current measurement noise (peak)4
High range:
Low range:
45 mA
30 mA
22 mA
17 mA
10 mA
7 mA
6 mA
4 mA
4 mA
2 mA
Keysight N6900/N7900 Series Operating and Service Guide
45
1 Quick Reference
Summary of Contents for N6900 Series
Page 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Page 2: ......
Page 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Page 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Page 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...