1 kW Models
High limit
Low limit
2 kW Models
High limit
Low limit
N6950A/N7950A
0 to 3800 µF
0 to 190,000 µF
N6970A/N7970A
0 to 7600 µF
0 to 380,000µF
N6951A/N7951A
0 to 1000 µF
0 to 50,000 µF
N6971A/N7971A
0 to 2000 µF
0 to 100,000 µF
N6952A/N7952A
0 to 240 µF
0 to 12,000 µF
N6972A/N7972A
0 to 480 µF
0 to 24,000 µF
N6953A/N7953A
0 to 100 µF
0 to 5600 µF
N6973A/N7973A
0 to 200 µF
0 to 11,200 µF
N6954A/N7954A
0 to 60 µF
0 to 3000 µF
N6974A/N7974A
0 to 120 µF
0 to 6000 µF
N6976A/N7976A
0 to 50 µF
0 to 2,800 µF
N6977A/N7977A
0 to 30 µF
0 to 1,500 µF
Front Panel Menu Reference
SCPI Command
Select Output\Advanced\Bandwidth.
Select either 1 (High or 0 (Low). If desired, enter the pole
frequency in the Frequency field. Then press Select.
To select the compensation bandwidth:
To specify the pole frequency:
Set the Output Resistance
Output resistance programming is mainly used in battery testing applications and only applies in
Voltage Priority mode. It is used to emulate the internal resistance of a non-ideal voltage source such
as a battery. Values are programmed in ohms. Model-specific resistance programming ranges are as
follows:
1 kW Models
Range
2 kW Models
Range
2 kW High Voltage
Range
N6950A/N7950A
0 to 0.1
Ω
N6970A/N7970A
0 to 0.05
Ω
N6976A/N7976A
0 to 6.8
Ω
N6951A/N7951A
0 to 0.4
Ω
N6971A/N7971A
0 to 0.2
Ω
N6977A/N7977A
0 to 12.8
Ω
N6952A/N7952A
0 to 1.6
Ω
N6972A/N7972A
0 to 0.8
Ω
N6953A/N7953A
0 to 3.4
Ω
N6973A/N7973A
0 to 1.7
Ω
N6954A/N7954A
0 to 6.4
Ω
N6974A/N7974A
0 to 3.2
Ω
Front Panel Menu Reference
SCPI Command
Select Output\Advanced\Resistance.
Specify an Output Resistance value. Then check the
Enable box. Then press Select.
To enable output resistance:
To select a resistance of 0.5 ohms:
Enable the Output
Because of internal circuit start-up procedures and any installed relay options, OUTPut ON may take
tens of milliseconds to complete its function. OUTPut OFF delays may also be in effect. For more
information regarding output turn-on and turn-off delays, refer to
.
Keysight N6900/N7900 Series Operating and Service Guide
109
4 Using the Advanced Power System
Summary of Contents for N6900 Series
Page 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Page 2: ......
Page 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Page 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Page 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...