![Keysight Technologies N6900 Series Operating And Service Manual Download Page 335](http://html1.mh-extra.com/html/keysight-technologies/n6900-series/n6900-series_operating-and-service-manual_1962217335.webp)
N7953A/N7973A
N7953A/N7973A Test Record
Report Number ______
Date__________
Test Description
Model
Min. Specs
Results
Max. Specs
Voltage Programming & Readback
Minimum voltage (Vout):
Voltage measured over interface:
High voltage (Vout):
Voltage measured over interface:
Both
Both
Both
Both
+ 54 mV
Vout – 6 mV
59.976 V
Vout – 24 mV
_______
_______
_______
_______
+ 66 mV
Vout + 6 mV
60.024 V
Vout + 24 mV
CV Load Effect:
Both
– 2 mV
_______
+ 2 mV
CV Ripple and Noise
peak-to-peak:
rms:
Both
Both
N/A
N/A
_______
_______
+ 9 mV
+ 1 mV
Transient response @ 100 µs:
Both
– 150 mV
_______
+ 150 mV
Current Programming & Readback
Minimum current (Iout):
Current measured over interface:
High current (Iout):
Current measured over interface:
N7953A
N7973A
N7953A
N7973A
N7953A
N7973A
N7953A
N7973A
– 2.5 mA
– 5 mA
Iout – 2.5 mA
Iout – 5 mA
16.6908 A
33.2817 A
Iout – 0.0092 A
Iout – 0.0183 A
_______
_______
_______
_______
_______
_______
_______
_______
+ 2.5 mA
+ 5 mA
Iout + 2.5 mA
Iout + 5 mA
16.7092 A
33.3183 A
Iout + 0.0092 A
Iout + 0.0183 A
Low Current Measurement Range:
N7953A
N7973A
Iout – 0.0011 A
Iout – 0.0023 A
_______
_______
Iout + 0.0011 A
Iout + 0.0023 A
CC Load Effect:
N7953A
N7973A
– 1 mA
– 1.5 mA
_______
_______
+ 1 mA
+ 1.5 mA
Current Sink Tests
10% of current rating:
100% of current rating:
N7953A
N7973A
N7953A
N7973A
– 1.6732 A
– 3.3363 A
– 16.7092 A
– 33.3183 A
_______
_______
_______
_______
– 1.6668 A
– 3.3237 A
– 16.6908 A
– 33.2817 A
N7953A Settings
N7973A Settings
Voltage Programming & Readback Min:
Voltage Programming & Readback High:
CV Load Effect, CV Ripple and Noise:
Transient Response:
Current Programming & Readback Min:
Current Programming & Readback High:
Low Current Measurement Range:
CC Load Effect:
10% of current rating (Isink):
100% of current rating (Isink):
Voltage priority: 60 mV, 16.7 A
Voltage priority: 60 V, 16.7 A
Voltage priority: 60 V, 16.7 A
Voltage priority: 60 V, 8.35 A to 16.7 A
Current priority: 60 V, 0 A
Current priority: 60 V, 16.7 A
Current priority: 60 V, 1.67 A
Current priority: 60 V, 16.7 A
Current priority: 60 V, - 1.67 A
External supply: 60 V, 1.837 A
Current priority: 60 V, - 16.7 A
External supply: 60 V, 18.37 A
Voltage priority: 60 mV, 33.3 A
Voltage priority: 60 V, 33.3 A
Voltage priority: 60 V, 33.3 A
Voltage priority: 60 V, 16.7 A to 33.3 A
Current priority: 60 V, 0 A
Current priority: 60 V, 33.3 A
Current priority: 60 V, 3.33 A
Current priority: 60 V, 33.3 A
Current priority: 60 V, - 3.33 A
External supply: 60 V, 3.66 A
Current priority: 60 V, - 33.3 A
External supply: 60 V, 36.6 A
Keysight N6900/N7900 Series Operating and Service Guide
335
7 Verification and Calibration
Summary of Contents for N6900 Series
Page 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Page 2: ......
Page 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Page 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Page 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...