The common delay offset assures that the user-programmed turn-on delays will be synchronized to
start at the completion of the common delay offset. Query the delay offset of each unit and use the
slowest delay as the common delay offset.
Front Panel Menu Reference
SCPI Command
Select Output\Sequence\Couple.
The Max delay offset for this frame field displays the delay
offset of the unit. Enter the delay offset value of the slowest unit
in the Delay offset field in milliseconds. Then press Select.
To query the delay offset of the slowest
unit:
Use the delay offset of the slowest unit to
specify the common delay offset
Keysight N6900/N7900 Series Operating and Service Guide
131
4 Using the Advanced Power System
Summary of Contents for N6900 Series
Page 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Page 2: ......
Page 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Page 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Page 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...