![Keysight Technologies N6900 Series Operating And Service Manual Download Page 251](http://html1.mh-extra.com/html/keysight-technologies/n6900-series/n6900-series_operating-and-service-manual_1962217251.webp)
l
If the power-on state is set to 0 with no state stored, a self-test error "file not found; 0 state" is gen-
erated and the instrument is set to the *RST state.
OUTPut:PROTection:CLEar
Resets the latched protection. This clears the latched protection status that disables the output when
a protection condition occurs (see
).
Parameter
Typical Return
(none)
(none)
Clears the latched protection status: OUTP:PROT:CLE
l
All conditions that generate the fault must be removed before the latched status can be cleared.
The output is restored to the state it was in before the fault condition occurred.
l
If a protection shutdown occurs during an output list, the list continues running even though the
output is disabled. When the protection status is cleared and the output becomes enabled again,
the output will be set to the values of the step that the list is presently at.
OUTPut:PROTection:MODE HIGHZ|LOWZ
OUTPut:PROTection:MODE?
Selects the turn-off behavior for all protection conditions as follows (see
):
High Impedance - the output is disconnected without actively sinking current. Without active current
sinking, output energy will take longer to dissipate - as downprogramming is solely determined by the
unit's passive internal network.
Low Impedance - the output voltage is programmed to zero, then disconnected. Maximum negative
current sinking occurs for 2 ms during the turn-off transition.
Parameter
Typical Return
HIGHZ|LOWZ, *RST LOWZ
HIGHZ or LOWZ
Sets protection behavior to High impedance: OUTP:PROT:MODE HIGHZ
OUTPut:PROTection:TEMPerature:MARGin?
Returns the minimum difference between the internal temperature sensors and the over-
temperature trip level. The margin is returned in degrees Celsius.
Parameter
Typical Return
(none)
<margin value>
Returns the temperature margin: OUTP:PROT:TEMP:MARG?
6 SCPI Programming Reference
251
Keysight N6900/N7900 Series Operating and Service Guide
Summary of Contents for N6900 Series
Page 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Page 2: ......
Page 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Page 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Page 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...