Parameter
Typical Return
AHOur|CURRent|POWer|VOLTage|WHOur,
*RST VOLTage
AHO, CURR, POW, VOLT, or WHO
Selects the power function for comparator 1: SENS:THR1:FUNC POW
SENSe:THReshold<1|2|3|4>:OPERation GT|LT
SENSe:THReshold<1|2|3|4>:OPERation?
Sets the operation type for comparator 1,2,3 or 4. GT (greater than) specifies that the signal will be
true if the measurement is greater than the threshold level. LT (less than) specifies that the signal will
be true if the measurements less than the threshold level.
Parameter
Typical Return
GT|LT, *RST GT
GT or LT
Selects the greater than operation for comparator 1: SENS:THR1:OPER GT
SENSe:THReshold<1|2|3|4>:AHOur[:LEVel] <
value
>|MIN|MAX
SENSe:THReshold<1|2|3|4>:AHOur[:LEVel]? [MIN|MAX]
SENSe:THReshold<1|2|3|4>:CURRent[:LEVel] <
value
>|MIN|MAX
SENSe:THReshold<1|2|3|4>:CURRent[:LEVel]? [MIN|MAX]
SENSe:THReshold<1|2|3|4>:POWer[:LEVel] <
value
>|MIN|MAX
SENSe:THReshold<1|2|3|4>:POWer[:LEVel]? [MIN|MAX]
SENSe:THReshold<1|2|3|4>:VOLTage[:LEVel] <
value
>|MIN|MAX
SENSe:THReshold<1|2|3|4>:VOLTage[:LEVel]? [MIN|MAX]
SENSe:THReshold<1|2|3|4>:WHOur[:LEVel] <
value
>|MIN|MAX
SENSe:THReshold<1|2|3|4>:WHOur[:LEVel]? [MIN|MAX]
These commands select the threshold level for comparators 1,2,3 or 4. This becomes the qualifying
measurement threshold for generating a true signal.
AHOur selects the amp-hour level in hours.
CURRent selects the current level in amperes.
POWer selects the power level in Watts.
VOLTage selects the voltage level in volts.
WHOur selects the watt-hour threshold level in hours.
Parameter
Typical Return
0 to maximum, *RST 0
<level value>
Selects a 1 watt-hour threshold for comparator 1: SENS:THR1:WHO 1
6 SCPI Programming Reference
261
Keysight N6900/N7900 Series Operating and Service Guide
Summary of Contents for N6900 Series
Page 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Page 2: ......
Page 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Page 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Page 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...