Keysight N5990A MIPI M-PHY Receiver Test User Guide
203
HS Tests
5
Figure 123
Example HTML Viewer for Test 2.1.10-HS-RX Sync Length Verification
Table 33
Test 2.1.10-HS-RX Sync Length Verification data table
Parameter Name
Parameter Description
Result
"Pass"/"Fail" - If the value is "Fail", the DUT does not support the tested sync length otherwise "Pass".
Tested HS_Sync
It is the tested sync length value.
Min Passed
It is the shortest sync length value supported by the DUT.
Min Tested
It is the shortest sync length that is tested.
Max Passed
It is the maximum sync length value supported by the DUT.
Max Tested
It is the maximum sync length value that is tested.
Tested Amplitude
It is the value of the tested differential voltage amplitude.
Tested Offset
It is value of tested common mode voltage.