Keysight N5990A MIPI M-PHY Receiver Test User Guide
59
N5990A M-PHY Station
2
Figure 28
M8020 ISI dialog
The preset can be selected as:
•
Physical Trace
: In this case the ISI is not generated internally with the
M8020. The ISI is added by including physical traces in the setup.
• MPHY G3A Ch1, MPHY G3A Ch2, MPHY G3B Ch1, MPHY G3B Ch2,
MIPI Short, MIPI Standard and MIPI Long are pre-defined presets of the
M8020.
•
Custom
: The preset is defined by selecting the following properties:
•
Mode
: Two pairs Frequency/Insertion Loss must be defined to
characterize the preset.
•
If
One Point
mode is selected, the first point is pre-defined as
0Hz/0dB.
•
In
Two Point
mode, the two
Frequency/Insertion Loss
points
can be defined.
•
Slope
: It depends on the points defined. It must be between -6,00dB
and -0,01dB.
•
Insertion Loss Offset
: It is the insertion loss
at 0Hz.
•
Frequency 1
: First frequency point.
•
Insertion Loss 1
: Insertion loss applied to the first frequency point.
•
Frequency 2
: Second frequency point.