Keysight N5990A MIPI M-PHY Receiver Test User Guide
273
Sys Burst Tests
8
Parameter Name
Parameter Description
Result
"Pass"/"Fail" - If the value is "Fail", the amplitude tolerance is below the spec limits.
Amplitude
It is the differential voltage amplitude value to be tested.
Offset
It is the offset common mode voltage value to be tested.
Min Passed Amplitude
It is the minimum amplitude value, where the DUT works without errors.
Min Spec Amplitude
It is the minimum amplitude value, where the DUT must work successfully.
Max Passed Amplitude
It is the maximum amplitude value, where the DUT works without errors.
Max Spec Amplitude
It is the maximum amplitude value, where the DUT should work successfully.
Error Count
The number of errors that occurred during the observation time.