Keysight N5290/1A Service Guide 1-13
Safety and Regulatory Information
Environmental Requirements
Environmental Requirements
The environmental requirements shown below are characteristic for the system
and are based on the limitations of the PNA network analyzer used.
Ventilation Requirements: When installing the product in a cabinet, the
convection into and out of the product must not be restricted. The ambient
temperature (outside the cabinet) must be less than the maximum
operating temperature of the instrument by 4 °C for every 100 watts
dissipated in the cabinet. If the total power dissipated in the cabinet is
greater than 800 watts, then forced convection must be used
.
Samples of this product have been type-tested in accordance with the
Keysight Environmental Test Manual and verified to be robust against the
environmental stresses of storage, transportation and end-use; those
stresses include but are not limited to temperature, humidity, shock,
vibration, altitude, and power-line conditions. Test methods are aligned
with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3.
Table 1-2
N5290/1A Environmental Conditions (Operating)
Environment
Temperature
Operation
0
°
C to 40
°
C (41
°
F to 104
°
F)
Storage
–40
°
C to +65
°
C (–40
°
F to 158
°
F)
Measurement Calibration
20
°
C to 26
°
C (68
°
F to 79
°
F)
Performance Verification
Temperature must be within 1
°
C (1.8
°
F) of
the temperature at which the measurement
calibration was performed.
Relative Humidity
Type tested at 95%, +40
°
C (non-condensing)
Pressure Altitude
Type tested 0 to 4600 meters (~15,000 feet)
Table 1-3
N5292/3/5A Environmental Conditions (Operating)
Environment
Temperature
For indoor use only (unless specified
otherwise.)
Altitude up to
4,600 meters
Temperature
0 to 40 °C
Relative humidity
Type tested, 0 to 95% relative humidity,
non-condensing up to 40°C
Summary of Contents for N5222B
Page 3: ...3 ...
Page 4: ...4 ...
Page 10: ...6 Keysight N5292A User s and Service Guide Contents ...
Page 28: ...1 18 Keysight N5290 1A Service Guide Safety and Regulatory Information Site Preparation 1 ...
Page 86: ...3 50 Keysight N5290 1A Service Guide System Tests and Adjustments Adjustments 3 ...
Page 128: ...5 10 Keysight N5290 1A Service Guide Theory of Operation Theory of Operation 5 ...
Page 225: ...Installation Note Xxxxx xxxxx 3 ...