3
– The safety valve protects the high pressure system against
excessive pressure.
– This valve is set and sealed in the factory. Do not change the
setting.
When the water supply is scarce, the flow switch switches off the
burner.
– When the water supply is scarce, the flow switch switches off
the burner.
– Accomodates the switching head during spray jet operations.
– The flow switch (additional switching head) prevents the acti-
vation of large burner capacities during spray lance operation
(below 1,800 l/h) in order to avoid overheating.
– The burner stage 1 is released when there is function failure.
The safety temperature limiter switches off the burner when the
maximum permissible temperature is exceeded.
– The safety valve "steam stage" protects the installation
against excessive pressure in the steam stage.
– This valve is set and sealed in the factory. Do not change the
setting.
The exhaust temperature limiter switches off the burner when the
maximum permissible exhaust temperature is exceeded.
– When there is a pressure shortfall (1.2 MPa), the pressure
guard switches the operating mode "Operate with steam"
over to "Operate using hot water".
– The operating mode "Operate with steam" is released only
when the minimum pressure (1.4 MPa) is reached.
– A main switch that can be locked is to be installed at a safe
and easily accessible place to switch off the entire heating
unit.
– The main switch is to be switched off while carrying out any
repairs or maintenance jobs.
If a pump module other than the HDI 38/12 is used, you must
check if this module has a pressure limitation (max. 1.6 MPa). If
this is not the case, you must install an additional safety valve (or-
der no. 6.412-271.0) at the input.
Safety Devices
Safety valve
Safety switch for water scarcity
Water shortage safeguard
Switch head for spray jet operation (with upgrade kit
spray jet only)
Safety temperature limiter
Safety valve "steam stage" (upgrade kit for steam
stage only)
Temperature stop for exhaust gases
Pressure monitor (upgrade kit for steam stage only)
Main switch
Pump module
25
EN
Summary of Contents for HWE 4000 Gas
Page 2: ...2...
Page 13: ...11 Ma blatt c Brennkammer ausziehen d Kesselmantel abnehmen 13 DE...
Page 33: ...11 Specifications sheet c Pull out the burner chamber d Remove the boiler sleeve 33 EN...
Page 53: ...11 Feuille de mesure c Sortir la chambre de br leur d Enlever le manteau de chaudi re 53 FR...
Page 93: ...11 M ttblad c Dra ut br nnkammare d Ta av beh llarens mantel 93 SV...
Page 105: ...3 1800 l h 1 1 2 MPa 1 4 MPa HDI 38 12 1 6 MPa 6 412 271 0 105 EL...
Page 110: ...8 ON Not Aus 95 C 10 10 tmax 100 C 10 2 MPa 80 C 110 EL...
Page 113: ...11 c d 113 EL...
Page 114: ...12 K rcher 30 10 dH 120 750 10 114 EL...
Page 115: ...13 K rcher RM 100 6 287 008 RM 101 6 287 013 RM 100 HWE 4000 20 RM 81 5 115 EL...
Page 118: ...16 DGRL 97 23 E IEC 60364 1 1x 10A EN 12729 BA 40 C 118 EL...
Page 119: ...17 VIU GVU 0 1 MPa 1 1 0 005 MPa 50 mbar 119 EL...
Page 120: ...18 120 EL...
Page 125: ...3 1500 1 1 2 1 4 HDI 38 12 1 6 6 412 271 0 125 RU...
Page 127: ...5 S1 P1 P2 M M1 1 16 27 A M30x1 5 B M30x1 5 C 20 3x1 5 2 12x1 2 A B C 7 8 28 12 11 9 127 RU...
Page 130: ...8 95 C 10 10 1 t 100 C 10 2 80 C 130 RU...
Page 133: ...11 c d 133 RU...
Page 134: ...12 30 10 dH 120 750 10 134 RU...
Page 135: ...13 Karcher RM 100 6 287 008 RM 101 6 287 013 RM 100 HWE 4000 20 RM 81 5 135 RU...
Page 138: ...16 DGRL 97 23 EG IEC 60364 1 1x 10A EN 12729 BA 40 C 138 RU...
Page 139: ...17 VIU GVU 0 1 1 1 0 005 50 139 RU...
Page 140: ...18 140 RU...
Page 153: ...11 M ret lap c g skamr t kih zni d Kaz nburkolatot levenni 153 HU...
Page 173: ...11 P ehled rozm r c Vyta en spalovac komory d Sejmut pl t kotle 173 CS...
Page 193: ...11 Arkusz z wymiarami c Wyj komor spalania d Zdemontowa p aszcz kot a 193 PL...
Page 203: ......
Page 204: ...http www kaercher com dealersearch...