6. Description of Parameters
- 178 -
Set the
programmable card
to activate.
Set the
drive
outputs.
0
PLC program
1
control
PLC program modified
PLC controls
digital output
(units position
of A7-05)
0: output invalid
1: output valid
0
PLC program
1
control
PLC controls
digital output
(tens position of A7-05)
0: output invalid
1: output valid
0
PLC program
1
control
PLC controls
digital output.
(units position
of A7-05)
0: output invalid
1: output valid
0
PLC program
1
control
PLC controls
FMP output.
(A7-03)
0.0% to 100.0%
Base value of percentage is
FMP output max. frequency
(F5-09).
Control mode
(ten thousands
position
of A7-01)
0
1
AC drive control
(See details in
group F5)
PLC program
control
PLC controls
AO1 output
(A7-04)
0.0% to 100.0%
Base value of percentage
is 10 V or 20 mA.
AO1
FMP
(FM used as pulse
output)
Control mode
(thousands
position
of A7-01)
DO1
Control mode
(hundreds
position
of A7-01)
Relay1
(T/A-T/B-T/C)
Control mode
(tens position
of A7-01)
FMR
(FM used as digital
output)
Control mode
(units position
of A7-01)
AC drive control
(See details in
group F5)
AC drive control
(See details in
group F5)
AC drive control
(See details in
group F5)
AC drive control
(See details in
group F5)
Figure 6-53 User programmable function (2)
Figure 6-54 The user programmable use schematic (3)
PLC program modified
The value of A7-09 is
determined by the user
programmable card.
6
PLC program modified
The value of A7-08 is
determined by the user
programmable card.
PLC program modified
The value of A7-06 is
determined by the user
programmable card.
PLC program modified
.
The value of A7-07 is
determined by the user
programmable card.
The frequency reference is set
via communication.
For details, see F2-09 and A0-01
80 to 89: User-defined
fault code
0: No fault
-100.0% to 100.0%
The base value of the percentage
is F0-10 (Max. frequency).
The frequency reference is set
via communication.
For details, see section 6.2.
7: Fault reset
6: Decelerate to stop
5: Coast to stop
4: Reverse jog
3: Forward jog
2: Reverse run
The running command is
given by the communication.
Set F0-02 = 2.
1: Forward run
0: No command
Set the
programmable card
to activate.
Fault
-200.0% to 200.0%
The base value of the percentage
is rated motor torque.
Torque
reference
Frequency
reference
Command
A7-00 = 1
A7-00 = 1