Appendix B Parameter Table
12
- 337 -
Para. No.
Para. Name
Setting Range
Default
Property
Page
F5-21
DO2 output delay
0.0s to 3600.0s
0.0s
☆
F5-22
DI active mode selection 1
00000 to 11111
00000
☆
Para. No.
Para. Name
Setting Range
Default
Property
Page
Group F6: Start/Stop Control
F6-00
Start mode
0: Direct start
1: Catching a spinning motor
2: Pre-excited start
3: SVC quick start
0
☆
F6-01
Mode of catching a spinning motor
0: From stop frequency
1: From 50 Hz
2: From max. frequency
0
★
F6-02
Speed of catching a spinning
motor
1 to 100
20
☆
F6-03
Start frequency
0.00 to 10.00 Hz
0.00 Hz
☆
F6-04
Start frequency holding time
0.0s to 100.0s
0.0s
★
F6-05
DC injection braking 1 level/Pre-
excitation level
0% to 100%
50%
★
F6-06
DC injection braking 1 active time
/Pre-excitation active time
0.0s to 100.0s
0.0s
★
F6-07
Acceleration/Deceleration mode
0 to 2
0
★
F6-08
Time proportion of S-curve start
segment
0.0% to (100.0%
– F6-09)
30.0%
★
F6-09
Time proportion of S-curve end
segment
0.0% to (100.0%
– F6-08)
30.0%
★
F6-10
Stop mode
0: Decelerate to stop
1: Coast to stop
0
☆
F6-11
DC injection braking 2 start
frequency
0.00 Hz to maximum
frequency
0.00 Hz
☆
F6-12
DC injection braking 2 delay time
0.0 to 100.0s
0.0s
☆
F6-13
DC injection braking 2 level
0% to 100%
50%
☆
F6-14
DC injection braking 2 active time
0.0s to 100.0s
0.0s
☆
F6-15
Braking use ratio
0% to 100%
100%
☆
-
F6-18
Catching a spinning motor current
limit
30% to 200%
Model
dependent
★
-
F6-21
Demagnetization time (effective
for SVC)
0.00s to 5.00s
Model
dependent
☆
-