71
Fig. 12.3.2-1
Fig. 12.3.2-2
30656E--
Technical documentation
Argus HSG
12.3.2 Service task - replace motor
Spline shaft (not visible)
Motor
Clamping screw
Opening in holding plate
Holding plate
Front xing screws
Shock absorber
Replace motor
Disconnect voltage to unit.
Unscrew the clamping screw until the thread is
no longer visible in the opening of the holding
plate.
Loosen the two front xing screws.
Remove the holding plate.
Pull out the motor from the spline shaft seat.
Insert the new motor: gently press the spline
shaft into the spline shaft seat.
The spline shaft must be correctly tted into
the spline shaft seat. Gentle force is suf cient,
do not press too hard.
Reposition the holding plate.
Tighten the two front xing screws.
Tighten the clamping screw.